Ekra X4 Screen Printer. IBE SMT Inventory ID: Ekra Serial Number: X Vintage: Details. VAC 16A Under Stencil Cleaner. results Ekra X4 Ekra X4 Ekra X4 IBE SMT Inventory ID: Ekra Serial Number : Vintage: Details •Vacuum Tooling Click Here for. The X4-Prof features the exceptional. EKRA ease of use and flexibility which are unmat- ched. The X4-Prof can be used for the application of solder paste and.

Author: Nikoran Shaktirn
Country: Sudan
Language: English (Spanish)
Genre: History
Published (Last): 11 May 2017
Pages: 476
PDF File Size: 4.28 Mb
ePub File Size: 12.65 Mb
ISBN: 320-9-38567-766-5
Downloads: 81460
Price: Free* [*Free Regsitration Required]
Uploader: Visho

Instructions concerning the software version V 4. This model is dedicated to small batch size production and prototyping purposes.

EKRA X4 for sale (used, price) #, > buy from CAE

The service menu is displayed. Remove the two alignment pins and paste up the calibrating holes of the upper calibration ledge. It is a high speed, high performance printer with optimized triple transport system HSP. Evaluation of Camera C Gerber or CAD data are not required. After you have finalised the configuration, make sure that the camera is exactly parallel to the table by using a water level. Set the snap off to 0. The maximum print format is x mm The lower calibration ledge consists of the assembly block and the calibration ledge.

  LE STRAORDINARIE AVVENTURE DEL BARONE DI MUNCHAUSEN PDF

Simple inspection programming using an automatic teach-in process for the pad positions. A new easy camera cali If the focus is not sufficiently precise, loosen the fastening screws of the camera slightly and move them horizontally until the focus has reached the optimum level of precision.

Always start by adjusting the top focus since this position is held wkra place by the fixed screen support ledges and cannot be changed. The sideways guided squeegee traverse and the adjustable squeegee pressure, ensure a constant, high quality print. wkra

Use the two alignment pins to check the position. Select Calibration fiducial 1 If the camera is not already placed on the left calibration hole,move the camera to this hole by changing the X and Y coordinates or using the manual button. Use the same light settings as in the camera menue Execute the function? The ekraa is equipped with one CCD camera looking up and one looking down. The substrate is then manually aligned using high resolution cameras for reliable recognition of fiducials or other layout features.

Simple operation and short set-up times all belong to the application oriented concept. Enter the two calibration holes as fiducials 1 and 2. Simple operation, short conversion times all belong to the application oriented concept. ekrra

Stiff as well as flexible materials x44 as PCBs, glass, ceramic or metal up to a thickness of 30 mm can be printed. You are prompted to enter the password.

  872C A5N18 A2 PDF

Ortak Elektronik

PCB strength and standard support blocks together 1. Both elements together reach a total height of 88 mm. Adjust the lighting conditions to achieve the right level of contrast. Adjust the focus to the upper calibration fiducial by loosen the fastening screws of the camera slightly and move the camera horizontally until the focus has reached the optimum level of precision. XM — Manual screen and stencil printing system: Direct the camera view downward.

It should be possible to enter the alignment pins with ease.

In order to provide maximum sharpness for the pictures x up, the focus of the objective has been optimised before the camera was attached to the holder. The assembly block is fastened with screws to the table plate, after which the calibration ledge is screwed to the assembly block.

The sharp focus of the top-to-bottom pictures is assured by adjusting the level of the table inspecting position. Quick clamp adapter systems of various manufacturers can easily be integrated.