This Standard is part of a series for plumbing and drainage, as follows: Water used for mixing concrete and cement mortar shall be free from. A O T F A H O A Australian/New Zealand Standard™ Plumbing and drainage Part 1: Water .. (b) Bends in pipes shall be free from wrinkling and flattening. of Australia and Part 6 of the Plumbers Licensing and Plumbing Standards Regulations The PCA. is now available to download (free of charge ).

Author: Tojazuru Kazrakus
Country: Congo
Language: English (Spanish)
Genre: Art
Published (Last): 7 March 2009
Pages: 243
PDF File Size: 11.66 Mb
ePub File Size: 10.31 Mb
ISBN: 819-2-58476-577-4
Downloads: 95685
Price: Free* [*Free Regsitration Required]
Uploader: Tebar

Member Benefits Check out the amazing benefits available to MPAQ members and how you can take advantage of the benefits on offer! In many parts of Australia and New Zealand the maintenance of the property service is the responsibility of the network utility operator. A wall -hung urinal is equivalent to one stall.

This Standard is part of a series for plumbing and drainage, as follows: The tank shall be drained after disinfection and flushed out with drinking water prior to being put back into service. Where the device is fitted with test taps, their location shall ensure the clearance necessary for the performance of the applicable test procedure and maintenance as defined in AS All standpipes connected to the water service shall be securely supported by fixing to walls of buildings, or other rigid supports.

A database of authorized products is available from w vv w. Sawn and round timber 1 Elastomeric seals for waterworks purposes Using the Master Plumber Logo for Branding! Find out more about Legionella and Legionella Legislation!

Where velocity would have exceeded the design maximum of 3. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the back cover. This is the distance, in metres, from the point where the minimum available pressure head is known e.

See Appendix F for examples of devices relative to levels of protection. Between editions, amendments may be issued. As an example, the inflow rate plumbint a 20 mm orifice with an inlet pressure of kPa would be 6.

  A FORTUNATE LIFE AB FACEY PDF

Suggested minimum thicknesses for insulations of various thermal conductivity ranges are given in Tables 5,5 and 5. To get your free Office download, visit Office. It shall have a minimum characteristic compressive strength of 20 MPa.

Where installations are to the relevant sections of this Standard, the following additional requirements of Clause Each valve shall be separately sized to cater for the total simultaneous demand see Figure The space between the partition walls shall be arranged to ensure that any leakage shall not be able to enter the other compartment of the tank and it shall be drained so that any discharge is external and readily noticed.

Plumbing: Home

Where there is no such program, these devices shall not be fitted and the standard air gap requirements shall apply. Glossary of terms View the guide below for more information. The use of croxed joints without rubber olives is permitted in New Zealand. Check out the upcoming courses!

Full text of “AS-NZS Plumbing and drainage – Part 1: Water services”

In general, thrust blocks shall be constructed of concrete with one side bearing against a firm vertical or horizontal face of the excavation, as appropriate, and designed so that the full hydrostatic forces in the piping are transmitted to the surrounding soil without the maximum bearing pressures of the soil and piping material being exceeded see Figure 5. This is particularly important if at the completion of your course you intend to apply for a license building, plumbing etc with Fair Trading.

For an example, see Figure F7, Appendix F. IO 6 2 Sink standard tap 0. In the case standarsd multistorey residential dwellings, the index length and pressure drop may be different for each dwelling; however, it may not be necessary to individually size each dwelling where the index lengths and pressure drops are similar for a group of dwellings.

The Standards Council of New Zealand is the national authority responsible for the production of Standards. Tanks with dual water supply shall maintain the air gap plumving accordance with Clause 4. These standards are developed through an open process of consultation and consensus, in which all interested parties are invited to participate.

  ARDYSS COMPENSATION PLAN PDF

A2 h Single check valve testable SCVT SCVTs shall— i be located so as not to be subjected to freezing; ii have isolating valves installed immediately upstream and downstream of the device; iii be fitted in an accessible position; and iv be used only in fire services. Record the password you create, for future use. Members can keep on top of employees Leave Entitlements here! Be sure to fill in any line with a red asterisk. Compliance with the air gap criteria shall be verified see Clause 4.

Need assistance Performance Managing employees? The maximum quantity of water to be discharged per flush shall be in accordance with Table For electrical safety precautions see also Clause 5. Taps that continue to run are connected to the non-drinking water service and should be clearly identified with appropriate warning signs.

The meter shall be fitted above ground in an accessible position. Registered air gaps and registered break tanks Safe working in a confined space Timbers — Classification into strength groups Plumbing xtandards drainage No backflow prevention required see Figure 7,1.

A2 I h Home fire sprinkler systems, AS 21 Check out the amazing benefits available to MPAQ members and how you can take advantage of the benefits on offer! The height of the highest fixture outlet in Unit 12 is 13 m above the main therefore: The pulmbing section of pipe shall be protected against corrosion by continuous wrapping in petrolatum tape to AWWA C21 7. For an example, see Table F2, Appendix F, Where fire hose reels are provided in a high hazard area, backflow prevention commensurate with the hazard level shall plumbingg provided.